Line-Interactive UPS Systems
Online UPS Systems
Servo Voltage Stabilizers
Line-Interactive Ups Systems

When mains power is present any voltage fluctuations within the specified range are corrected by the in-built automatic voltage regulator and fed to the load.

The built-in charger keeps the battery charged during this period.

When mains power fails the inverter draws power from the battery, converts it into a regulated A.C. Voltage and delivers to the load. The changeover from mains mode to battery mode and vice-versa is automatic and power is delivered to the load without interruption. In cases of overload and short circuit the unit automatically trips.

PROTECTS AGANIST
Power Failures
Voltage Fluctuations
Short-term Voltage dropouts
 
 
 
APPLICATIONS
Networks
Computer lefts
Data Processing Systems
EPABX Systems
Fax Machines
Office Automation
Standarad Specifications
Input Phase
Input Voftage Nominal
Input Voltage Range
Input Frequency
Input Frequency Range
Output Phase
Output Voltage On Mains
Output Voltage On Inverter
Output Frequency On Mains
Output Frequency On Inverter
Output Waveform On Mains
Output Waveform On Inverter
Load Power Factor
Rated Power in KWatts
Mains Voltage Regulation
Charger CC_CV Type Fully
Inverter
Protections


Indications Alarms Optional


Single Phase
230 Vac
170-270Vac
50 Hz
47-53 Hz
Single Phase
200-240 Vac
230 Vac Nominal
Same as Input
50 Hz
Same as Input
Quasi Sivewave
0.7
0.7 times KVA Rating
Automatic Voltage Regulator
Automatic Boost cum Float Charger
Pulse Width Modulated
Mains High/Low Voltage Output High/Low Voltage Over Load/ Short Circuit Battery Over/Under Charge
Software Interface Pure Sinewave Output on Inverter Batteries in-built with UPS
top
Online Ups Systems
 

True online double-conversion technology with galvanic isolation
When mains power is present, the UPS converts the input AC voltage to DC to charge the battery and to supply the inverter with energy. The inverter generates a slnewave AC voltage.

which is permanently available at the output of the UPS through an isolating transformer. If a problem occurs with the mains power supply, the battery delivers the necessary power to the inverter, additional bypass system which is integrated into the UPS guarantees the highest possible level of reliability: In cases of overload or short circuit, the bypass system automatically connects the mains power input directly through to the electrical load.

PROTECTS AGANIST
Power Failures
Voltage Fluctuations
Short-term Voltage dropouts
Interference
Voltage Surges
Disorted Waveforms
APPLICATIONS
Networks
Computer lefts
Data Processing Systems
Bio-medical equipment
Telecommunication systems
Automation technology systems
Standarad Specifications
Parameters
Capacity
Input Voltage Nominal
Input Voltage Range
Input Frequency Nominal

Input Frequency Range

Input Power Factor
Output Voltage Nominal

Output Voltage Regulation

Output Frequency Nominal

Output Frequency Range

Output Waveform
THD
Load Power Factor
Load Power Rating in KWatts
Transient Response
Efficiency
Rectifier Charger


Inverter


Protections

indications

Metering

Options

Single Phase
1.0KVA-50.0KVA
230Vac 33
1 70-270Vac
50Hz

47-53 Hz

0.95 with active filtering
230Vac

+/- 1%

50Hz

+/- 0.05%

Pure sinewave
< 3% [Linear]
O.Spf
0.8 Times KVA Rating

+/- 5V/1Cy.
>90%
CC-CV Fully automatic float cum boost charger

Adaptive sine-weighted pulse width modulated [IGBT]
Under/Over Voltage, Over Load/Short Ckt
Mains On, Inv. On Btty Low, Btty On, Trip
Analog/Digital for Input and Output
Static bypass Software interface
Three Phase
10.0KVA-200.0KVA
400Vac
295-465Vac
50Hz

47-53 Hz

0.95 with active filtering
400Vac

+/- 1%

50Hz

+/- 0.05%

Pure sinewave
< 2% [Linear]
O.Spf
0.8 Times KVA Rating

+/- 5V/1Cy.
>90%
CC-CV Fully automatic float cum boost charger

Adaptive sine-weighted pulse width modulated [IGBT]

Under/Over Voltage, Over Load/Short Ckt
Mains On, Inv. On Btty Low, Btty On, Trip
Analog/Digital for Input and Output
Static bypass Software interface
top
Servo Voltage Stabilizers
 

Voltage fluctuations in the mains power within the specified range, are automatically sensed continuously and the servo motor automatically moves the sliding contacts across the variac-buckboost transformer arrangement to make the required compensatory change in voltage. This ensures that a well regulated A.C. Voltage is available to the load. In cases of overload and short circuit the unit automaticallytrips.

PROTECTS AGANIST
Voltage Fluctuations
 
 
 
 
 
APPLICATIONS
Networks
Computer lefts
Data Processing Systems
Bio-medical equipment
Telecommunication systems
Automation technology systems
Standarad Specifications
Parameters
Capacity
Input Voltage Nominal
Input Voltage Range
Input Frequency Nominal

Input Frequency Range

Output Frequency
Output Voltage Nominal

Output Voltage Regulation

Output WaveForm

Load Power Rating in KWatts
Correction Speed
Connection
Insulation
Servo Motor

Sensing Circuit
Efficiency
Protections



Indications

User Controls


indications


Metering


Operating Ambient Temp

Single Phase
1.0KVA-20.0KVA
230Vac
1 70-270Vac
50Hz

47-53 Hz

Same as Input
230Vac

1%

Same as Input

Same as KVA Rating

35V/sec
Star
Class B
AC-Synchronous

Mains Isolated
98% [Approx]
Under/Over Voltage, Over Load


Input On, Output On Input Low, Input Hi
Auto/Manual, Voltage Adjust

Mains On, Inv. On Btty Low, Btty On, Trip

Analog/Digital for Input and Output [Selectable]

0-50C

Three Phase
30.0KVA-1000.0KVA
400Vac
295-465Vac
50Hz

47-53 Hz

Same as Input
400Vac

1%

Same as Input

Same as KVA Rating

60V/sec
Star
Class B
AC-Synchronous

Mains Isolated
98% [Approx]
Under/Over Voltage, Over Load


Input On, Output On Input Low, Input Hi
Auto/Manual, Voltage Adjust


Mains On, Inv. On Btty Low, Btty On, Trip

Analog/Digital for Input and Output [Selectable]

0-50C